Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Recirculating Chiller F-305 / F-308 / F-314 Operation Manual

Operation Manual Recirculating Chiller F-305 / F-308 / F-3147/42 Safety2 Intended use2.1 The Recirculating Chiller F-3xx has been designed and built as an item of laboratory equipment. It is intended to be used for cooling sealed circulation systems (e.g. Ro-tavapor R-300, reaction vessels).

Circulating Chillers - Da Vinci Laboratory Solutions Web Shop

Recirculating Chiller F-305 / F-314 : 5: Recirculating Chiller F-325 : 6: Recirculating chillers F-series : Volg ons . Da Vinci Laboratory Solutions B.V. - T +31 (0)10 258 1870 - Dit e-mailadres wordt .

BUCHI 11F30502 Model F-305 Recirculating Chiller, 550W at .

The Recirculating Chiller F-305 / F-308 / F-314 are specifically designed to work with laboratory equipment such as rotary evaporators, parallel evaporators, Kjeldahl, and extraction products. You .

Import Data and Price of CHILLER under HS Code 8419 | Zauba

ROTAVAPOR R-100SYSTEM, RECIRCULATING CHILLER F-305 ( USED FOR DSIR PURPOSE: Switzerland: Kolkata Air Cargo: PCS: 2: 360,828: 180,414: Nov 09 2016: 84199090: SHEAR PIN, PN:21306-8 FOR 18 XE-101/2/3/3(SUPPLY OF SHEAR PIN FOR DP EXCHANGERS & CHILLERS OF SDU: United Kingdom: Kolkata Air Cargo: PCS: 100: 147,939:

Rotavapor® R-300 System with Interface I-300 and .

Recirculating chiller F-305 Ecological recirculating chiller. Cooling capacity: 550 W at 15 °C. Temperature range: - 10 °C to +25 °C. Rotation knob for set temperature in steps of 0.1 °C. Lock of .

BUCHI Special Offer FatExtractor E-500

Recirculating Chiller F-305 · No water consumption · ECO-mode: saves energy and reduces heat emission by switching into a standby mode when not in use · Saves time thanks to instant start with automatic and dynamic pressure adjustment without waiting until chiller reaches it's set temperature *This offer is valid until 30/09/2020.

Rotavapor R-300 Technical data sheet - Cole-Parmer

Recirculating Chiller F-305 / F-308. The interface is the central control unit for all process parameters. Rotation speed, heating-, cooling-, vapor-temperature and pressure are perfectly synchronized to optimize the distillation process while increasing efficiency and convenience. All the "Rotavapor® Dynamic" systems are P+G coated.

Buchi R-300 | Vanguard Scientific Systems

The rotary evaporator R-300 system meets the highest expectations in convenience and versatility. It is bundled with the Vacuum Pump V-300, controlled by the Interface I-300 / I-300 Pro and can include the Recirculating Chiller F-305 / F-308. The interface is the central control unit for all process parameters.

Recirculating Chiller F-325 Item ID: BU11F32501 - In Vitro

The compressor in the chiller generates heat. The heat is blown out of the unit by a fan. The heat emission depends on the cooling capacity of the chiller. The heat emissions are: F-100: max. 300 W; F-105: max. 300 W; F-305: max. 300 W; F-308: max. 500 W; F-314: max. 1000 W; F-325: max. 1800 W

BUCHI F-305 OPERATION MANUAL Pdf Download.

Page 1 Recirculating Chiller F-305 / F-308 / F-314 Operation Manual.; Page 2 CH-9230 Flawil 1 E-Mail: [email protected] BUCHI reserves the right to make changes to the manual as deemed necessary in the light of experi- ence, especially with respect to structure, illustrations and technical details. This manual is copyrighted. Information from it may neither be reproduced, distributed, or .

recirculating chillers Equipment available in Mauritius

The Recirculating Chiller F-305 / F-308 / F-314 are specifically designed to work with laboratory equipment such as rotary evaporators, parallel evaporators, Kjeldahl, and extraction products. You .

Recirculating Chillers | Fisher Scientific

Recirculating Chillers HUBER™ Minichiller 280 Chiller The compact Minichiller is an economic and environmentally friendly cooling solution for many laboratory applications.

Product Details Lab Unlimited Online Shop | Lab Unlimited UK

Rotavapor® R-300 System with Interface I-300 without recirculating chiller F-305 Every Rotary Evaporator Rotavapor® R-300 will be delivered with a transparent PLASTIC+GLAS (P+G) safety coating, a vertical glass assembly (V), NS29/32, and a vacuum pump V-300. Interface, heating bath and recirculating chiller .

Chillers | New and Used Lab Chillers and Recirculators .

BUCHI Recirculating Chiller F-305 / F-308 / F-314. Price: Please Inquire. Condition: New. BUCHI Recirculating Chiller F-105. Price: Please Inquire. Condition: New. BUCHI Corporation Recirculating Chiller F-325. Price: Please Inquire. Condition: New. Refurbished Agilent HP 1100 G1330A/B Thermostat Chiller .

Recirculating Chiller F-305 / F-308 / F-314 The efficient .

The Recirculating Chiller F-305 / F-308 / F-314 are specifically designed to work with laboratory equipment such as rotary evaporators, parallel evaporators, Kjeldahl, and extraction products. You benefit from convenient central temperature setting, energy-saving ECO-mode, and auto-

Recirculating Chillers | Fisher Scientific

Recirculating Chillers HUBER™ Minichiller 280 Chiller The compact Minichiller is an economic and environmentally friendly cooling solution for many laboratory applications.

Search Results Details Lab Unlimited Online Shop | Lab .

Recirculating chiller F-305 Ecological recirculating chiller. Cooling capacity: 550 W at 15 °C. Temperature range: - 10 °C to +25 °C. Rotation knob for set temperature in steps of 0.1 °C. Lock of cooling temperature. In combination with Interfaces I-300 / I-300 Pro: Temperature setting/monitoring via interface, energy-saving eco-mode and .

recirculating chiller f-308

The Recirculating Chiller F-305 / F-308 / F-314 are specifically designed to work with laboratory equipment such as rotary evaporators, parallel evaporators, Kjeldahl, and extraction products. You benefit from convenient central temperature setting, energy-saving ECO-mode, and automatic start/stop when used in conjunction with the Rotavapor R .

New EASY PACK available! Proven all-in-one system with new .

Recirculating Chiller F-305/F-308 Example confi guration Order number Net price* (EUR) Rotavapor R-300, Vacuum Pump V-300 with Interface I-300 and Heating Bath B-301 with manual lift, coated .

recirculating chiller f-325

Recirculating Chiller F-325 Recirculating chiller with a cooling capacity of 2500 W at 15 °C. This chiller is not only cooling the Rotavapor® R-220 Pro but also opera-tes as a trolley and host of the Vacuum Pump V-600. Dimensions are (WxDxH): 1100 x 660 x .

India Import data of Chiller - Exim Pulse

0004171000 rc 2 basic recirculating chiller voltage 230v: 5: pcs: 132838: 664189: bangalore acc: duty: more: 43: 02-jun-16: 84198990: italy: mta chiller taeevo tech 161/p3 serial no : 2200277718: 1: unt: 553275: 553275: nhava sheva (jnpt) sea: duty: more: 44: 01-jun-16: 84198990: germany: chiller .

Rotavapor® R-300 System with Interface I-300 and .

Rotavapor® R-300 System with Interface I-300 and recirculating chiller F-305 Every Rotary Evaporator Rotavapor® R-300 will be delivered with a transparent PLASTIC+GLAS (P+G) safety coating, a vertical glass assembly (V), NS29/32, and a vacuum pump V-300. Interface, heating bath and recirculating chiller .

Rotavapor® R-300 System with Interface I-300 without .

Recirculating chiller F-305 Ecological recirculating chiller. Cooling capacity: 550 W at 15 °C. Temperature range: - 10 °C to +25 °C. Rotation knob for set temperature in steps of 0.1 °C. Lock of .

Recirculating Chillers | Fisher Scientific

Recirculating Chillers HUBER™ Minichiller 300 Chiller The compact Minichiller is an economic and environmentally friendly cooling solution for many laboratory applications.

11595224E en Recirculating Chiller F-305, F-308, F-314 06

The Recirculating Chiller F-305 / F-308 / F-314 cover a temperature range of -10 to + 25 °C. The chillers differ in the colling capacity to support various laboratory instruments. Recommended chiller when working at 15 °C cooling and 20 °C ambient temperature F-305 F-308 F-314 Cooling capacity at 15 °C550 W 900 W 1400 W

Rotavapor® R-300 System with Interface I-300 without .

Recirculating chiller F-305 Ecological recirculating chiller. Cooling capacity: 550 W at 15 °C. Temperature range: - 10 °C to +25 °C. Rotation knob for set temperature in steps of 0.1 °C. Lock of .

Import Data and Price of CHILLER under HS Code 8419 | Zauba

ROTAVAPOR R-100SYSTEM, RECIRCULATING CHILLER F-305 ( USED FOR DSIR PURPOSE: Switzerland: Kolkata Air Cargo: PCS: 2: 360,828: 180,414: Nov 09 2016: 84199090: SHEAR PIN, PN:21306-8 FOR 18 XE-101/2/3/3(SUPPLY OF SHEAR PIN FOR DP EXCHANGERS & CHILLERS OF SDU: United Kingdom: Kolkata Air Cargo: PCS: 100: 147,939:

Rotavapor R-300 Technical data sheet - John Morris Scientific

Recirculating Chiller F-305 / F-308. The interface is the central control unit for all process parameters. Rotation speed, heating-, cooling-, vapor-temperature and pressure are perfectly synchronized to .

Laboratory recirculation chiller - All industrial .

The Recirculating Chiller F-305 / F-308 / F-314 are specifically designed to work with laboratory equipment such as rotary evaporators, parallel evaporators, Kjeldahl, and extraction products. You .

Search Results Details Lab Unlimited Online Shop | Lab .

Recirculating chiller F-305 Ecological recirculating chiller. Cooling capacity: 550 W at 15 °C. Temperature range: - 10 °C to +25 °C. Rotation knob for set temperature in steps of 0.1 °C. Lock of .