Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Bioreactor at Best Price in India

- In fluidized bed bioreactors the waste water is fed upward to a bed of 0.4 to 0.5 mm sand or activated carbon. - Bed depths are in the range of 3 to 4 m - The specific surface area is about 100 m2/m3 of the reactor volume, which is greater than any of the other fixed film packing.

Single-Use Bioreactors - Cell Culture | Pall Corporation

Probably the most significant impact has been seen from the use of single-use bioreactors as an alternative to cleanable, re-usable systems. Single-use components have allowed for increased manufacturing flexibility, enhanced sterility assurance and reduced capital investment, as well as faster start-up of new facilities.

Pharmaceutical Best Practices | Bioreactor Operational .

Apr 02, 2009 · In general, an accuracy of ± 0.5°C is considered adequate for cell culture, although transient excursions may exceed that range with no impact to product quality or cell culture performance. Typical bioreactor temperature measurement devices are resistance temperature devices (RTDs), which are highly accurate, reproducible and only moderately .

Sparger and Surface Gas Transfer for Cell Culture Bioreactors

(1000-L) cell culture bioreactor, and resulted in increased titers. To assess how scale affects the performance of these spargers, we studied four bioreactors ranging in size from 15-L to 2500-L total volume, with the same sintered metal frit sparger design. We measured mass transfer coefficients for oxygen and carbon

Bioreactor Development for Stem Cell Expansion and .

Oxygen Tension. Studies in static culture systems have generally shown that low pO 2 decreases the rate of stem cell differentiation and may also enhance stem cell proliferation. For example, human [] and mouse [] ESCs were reported to expand more rapidly under 2–5% vs. 20% O 2, and hESC differentiation was decreased under 3–5% vs. 20% O 2 [].After a short lag period, .

Bioreactor Gas Control, Bubble-Free | PermSelect-MedArray

A cell culture bioreactor refers to a device or system meant to grow cells or tissues in the context of cell culture. Bioreactor processes can either be aerobic or anaerobic, but successful processes require effective management and quality control of gas composition and pH within the media.

Extractables from Single-Use Bioreactors and Impact on .

Jan 22, 2019 · Extractables from Single-Use Bioreactors and Impact on Cell Culture Performance Plastic single-use bioreactors are of interest to biopharmaceutical drug manufacturers due to their significant environmental and cost benefits and flexibility over stainless steel bioreactors.

Viral contamination in biologic manufacture and .

Apr 27, 2020 · Of the 18 contamination events reported to the CAACB, 7 were contained in cell culture bioreactors (Fig. 2). Noteworthy is the fact that in 3 of the events, virus-specific PCR tests performed .

Bioreactors for Suspension Culture, Cell Damage in Stirred .

Cell damage is directly affected by the aeration rate. Sparging-associated damage may be enhanced by impeller agitation. Cell damage caused by bubbles and foam can be significantly reduced by adding shear-protective substances (e.g. Pluronic®–F68) and/or antifoam agents (e.g. antifoam C) .

CellBRx ™ 2/10 | OmniBRx Biotechnologies

CellBRx ™ 2/10 bioreactor systems are more advisable for Allogenic Stem cell production on larger scale. The 2L scale bioreactor vessel accommodates approximately 35 m2 of surface area which is equivalent to the use of 55 No's of Cell Factories (CF-10).

Control of Dissolved Oxygen in Stirred Bioreactors

cesses, it is also important to provide the culture with oxygen. This is often solved by keeping a constant dissolved oxygen concentration. Figure 1 shows a drawing of a stirred bioreactor. In the reactor there is a liquid medium that contains cells and substrates. Air is sparged into

Extractables from Single-Use Bioreactors and Impact on .

Jan 22, 2019 · Extractables from Single-Use Bioreactors and Impact on Cell Culture Performance Plastic single-use bioreactors are of interest to biopharmaceutical drug manufacturers due to their significant environmental and cost benefits and flexibility over stainless steel bioreactors.

Propagation of plant cells in robust single-use bioreactors

In this model mixing and aeration can be introduced in a simple way without sparging and risk of foaming. Lingonberry cells were successfully cultivated in single-use cultivation bag and biomass accumulation reached promising levels (174 g/L) compared to shake flask (208 g/L) and stirred tank bioreactor cultivations (210 g/L).

Modeling of Biopharmaceutical Processes—Part 1: Microbial .

Jun 01, 2008 · A significant problem associated with sparging of mammalian cell cultures is cell death because of high shear, which occurs primarily because of bubble rupture at the liquid surface. 14 Surfactants such as Pluronic F-68 are typically added to cell culture media to prevent cells from sticking to bubbles as they rise through the liquid, but .

(PDF) Bioreactors – Technology & Design Analysis

A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text.

Biostat STR® Generation 3 Single-Use Bioreactor | Sartorius

Biostat STR® is engineered for highly efficient mixing and high oxygen transfer. In addition to the standard features, you can incorporate advanced options such as an integrated spectroscopy port, Repligen's XCell™ ATF cell retention device, BioPAT® process control tools and software, and sophisticated analytics.

Bioreactor Development for Stem Cell Expansion and .

Oxygen Tension. Studies in static culture systems have generally shown that low pO 2 decreases the rate of stem cell differentiation and may also enhance stem cell proliferation. For example, human [] and mouse [] ESCs were reported to expand more rapidly under 2–5% vs. 20% O 2, and hESC differentiation was decreased under 3–5% vs. 20% O 2 [].After a short lag period, human MSCs grew more .

The Impact of Sparging on Cell Culture in Bioreactors .

Sep 14, 2016 · A Tutorial on Bioprocessing: Cell Culture Optimization -- The Impact of Sparging with Parviz Shamlou

Recent advances in bioreactors for cell-based .

Apr 30, 2018 · Bioreactors for cell proliferation and differentiation. The therapeutic promise of stem cell-based technologies for the treatment of pathologies ranging from hair loss 1 to blindness 2 has precipitated the need for a cell-manufacturing sector to provide therapeutic allogeneic cells. Owing to the extensive infrastructure requirements and rigorous standards defined by regulatory agencies, the .

Viral contamination in biologic manufacture and .

Apr 27, 2020 · Of the 18 contamination events reported to the CAACB, 7 were contained in cell culture bioreactors (Fig. 2). Noteworthy is the fact that in 3 of the events, virus-specific PCR tests performed .

Stirred Tank Bioreactors - Cell Culture | Pall Corporation

"The large-volume production of viral vectors is typically achieved in bioreactors. However, the design of the bioreactor can have a significant impact on process performance. Brammer bio therefore invested time and resources to evaluate different potential bioreactor technologies, both on paper and in the process development lab.

Two Minute Tuesday Video Archive - WuXi Biologics

The Impact of Mixing on Cell Culture. The Impact of Sparging on Cell Culture. The Impact of Aeration on Cell Culture Part 1. The Impact of Aeration on Cell Culture Part 2. The Impact of pH on Cell Culture. Understanding the Role of Dissolved C02 & C02 on Cell Culture . Bioprocessing Cell Culture .

Air sparging for prevention of antibody disulfide bond .

Air sparging for prevention of antibody disulfide bond reduction in harvested CHO cell culture fluid. Mun M(1), Khoo S, Do Minh A, Dvornicky J, Trexler-Schmidt M, Kao YH, Laird MW. Author information: (1)Late Stage Cell Culture, Genentech, Inc., 1 DNA Way, South San Francisco, California, 94080.

Design and Performance of Single-Use, Stirred-Tank Bioreactors

Nov 17, 2016 · A typical maximum tip speed suggested to prevent such damage during cell culture in bioreactors is ~1.5 m/s (12). However, no theoretical reason or experimental evidence supports that value. Some researchers have reported values well over 1.5 m/s without cell damage in large-scale cell culture (13). Much lower values are available in the .

High quality automatic Fermentors and Bioreactors in .

ZENITH India presents a range of low-cost autoclavable and in-situ sterilizable laboratory Bioreactors and Fermentors designed for performance and ease of use. Using the latest in 16 bit microprocessor technology we offer fermentors and bioreactors that use multi-loop process control techniques to maximize yields in cell-culture and fermentation.

The Impact of Sparging on Cell Culture in Bioreactors .

The Impact of Sparging on Cell Culture in Bioreactors – Two Minute Tuesday Video. A Tutorial on Bioprocessing: Cell Culture Optimization — The Impact of Sparging.

Scale‐down simulators for mammalian cell culture as tools .

These bioreactors can reach volumes of up to 25 000 L for mammalian cell culture processes 3. Furthermore, it has been estimated that approximately 50% of the biologics will continue to be produced in bioreactor volumes of at least 5000 L 4. There are different approaches for scaling up a process from development to production scale.

NS0 cell damage by high gas velocity sparging in protein .

Recent developments in high cell density and high productivity fed‐batch animal cell cultures have placed a high demand on oxygenation and carbon dioxide removal in bioreactors. The high oxygen demand is often met by increasing agitation and sparging rates of air/O 2 in the bioreactors.

Single-Use Bioreactors Market by Product Type, End User .

Furthermore, the performance-efficiency of single-use bioreactors also creates value for the market players. In recent times, cellular studies, cell culture, and single-cell analysis have emerged as the catchphrases in the medical industry. In this scenario, the growth of the global single-use bioreactors market remains uncontested.

Controlling Cell Culture pH in Bioreactors - Cell Culture Dish

Oct 11, 2016 · 0 0 2 Total2 Controlling cell culture pH in bioreactors is critical to successful manufacturing. Most culture needs to be maintained in a specific narrow range of pH for maximum productivity. Typical pH range during bioproduction is 7.0± 1.0. Several factors affect pH including temperature, cell growth, lactic acid, and CO2 levels. Maintaining cell culture .