Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Water Chillers | Industrial Process Cooling | Temperature .

Temperature Control Units; Circulation units provide temperature stabilized fluid. Water units to 300°F. Oil units to 500°F. Evaporative Cooling Towers; Evaporative cooling for fluid temperatures from 70°F to 100°F. Non-ferrous units to 540 tons. Pump Systems & Reservoirs; For circulating your chilled or tower water to your process.

Test System Cooled Low Temperature Chiller

Test System Cooled Low Temperature Chiller (Test Air or Water) - OTT (Model OTT Custom shown) Utilized in lab testing, component, battery, & dynamometers to name a few. Low Temperature Chiller - OTT Spec Sheet. For more information, please visit our Test Chillers .

Low Temperature Test Chillers | Opti Temp

Chillers for low temperature process cooling, ultra-low temperature cooling and standard cooling systems. . extreme low temperature cooling and standard temperature cooling systems, designed by Opti Temp, Inc. OTT Series Low Temperature Chillers Operating Range -40°C to 88°C . Air or water cooled condensers. Chillers can be manufactured .

How Does A Chiller Work? - What Is A Chiller & How To .

How does a Chiller Work? In most process cooling applications, a pumping system circulates cool water or a water/glycol solution from the chiller to the process. This cool fluid removes heat from the process and the warm fluid returns to the chiller. The process water is the means by which heat transfers from the process to the chiller.

The Main Components of a Process Chiller - Drake .

Jun 25, 2020 · At the start of the cooling phase, the water or glycol mixture from your processes enters the evaporator. After it arrives, the process heat boils the refrigerant fluid, which converts it from a low-pressure liquid to a low-pressure gas. Pro tip: If you have temperature requirements, look for chillers that have low-temperature .

Design Temperature Difference for Chillers - HVAC School

Nov 13, 2018 · There are two different approach temps that i look at on a chiller: Condenser approach (cond sat temp – lvg cond water temp) Evaporator approach (lvg water temp – evap sat temp) Approach values should range in 0 – 3°f(0°K – 1.65°K), given that your flows are correct.

40 Ton Chiller – Air-cooled and Water-cooled | Cold Shot .

A 30 Ton model WCWC-480-E-RF water-cooled fluid chiller provides 480,000 BTU/Hr. of cooling capacity with 50°F leaving fluid temperature with 85°F incoming condensing water temperature. Water-cooled chillers are designed to dissipate process heat into a cooling tower or large water .

FTS Low Temperature Cooling Systems & Equipment - SP .

FTS Thermal Products offer low temperature cooling equipment for any thermal management requirement. Systems are available with contact, fluid or air cooling mediums with a wide variety of temperature ranges and heat load capacities. Eliminate costly and awkward expendable refrigerants such as dry ice and liquid nitrogen.

Solid State Cooling Systems: ThermoCube Liquid-to-Liquid

(down to -10°C with low temp option) (up to 65°C with high temp option) Ambient Temperature: 10°C to 40°C non-condensing: Stability / Repeatability: ± 0.05°C at constant load (even near ambient) Cooling Capacity (@ 20°C (with 20°C facility chilled water.

Process Chillers | Industrial Cooling | Liquid Cooling .

Our industrial process chiller products provide the cooling needs for food and beverage, liquid cooling and plastics with precise requirements addressed, including machine cooling, low-temperature applications, chemical processing, and high power equipment cooling. Arctic process chiller solutions serve a diverse clients base, from food and .

Used Process Chillers For Sale - American Chillers and .

Used Process American Chiller For Sale. 13,589.00 (List price is 43,745.00) 15 hp, Low Temperature Chiller, recirculating with Tank and pump, Copeland semi hermetic compressor, .

Low Temperature Chillers | BV Thermal Systems

The BV Thermal Systems Low Temperature Chillers offer continuous cooling with a temperature from -40° to +30°C. They are ideal for laboratories, and semiconductor, medical, pilot plants and custom applications that require accurate and precise ultra-low temperature control. Featuring a low profile design with high quality locking casters, the Low Temperature Chillers are optimized at your .

Low Temperature Process Cooling | Test Chillers from Opti Temp

Opti Temp has developed innovative rugged portable chiller designs in response to an increasing global demand for mobile applications. Our chillers have been designed to withstand broad temperature extremes from desert to arctic with capabilities of accurate process heating and process cooling.

Extraction Chillers - CBD & Cannabis | Ethanol, Ultra-Cold .

ultra-low temp chillers-70°f (-56.7°c) to -60°f (-51.11°c) fluid. freon cascade systems (r-507/r-508b)-70°f (-56.7°c) to -60°f (-51.11°c) fluid. hydrocarbon cascade systems (r290/r-170)-100°f (-73.3°c) to -71°f (57.22°c) fluid. liquid nitrogen exchange systems

Troubleshooting Common Chiller Problems - Process Cooling

Jul 01, 2008 · A closed or partially closed valve, failed pump, inadequate coolant volume or process line restriction might be preventing the adequate flow of liquid through the process coolant loop. Check the process and environmental conditions. The load on the chiller might be too great due to changes in the process or the ambient temperature.

Mydax Precision Process Cooling Liquid Chiller Systems .

Mydax Recirculating Liquid Chiller / Heater Process Control products are used in a variety of applications. Our precision heat transfer fluid temperature control cooling systems are used in many industries. Process control fluid temperatures available as low as -70°C (-94° F) or colder.More info >

Chiller - Wikipedia

A chiller is a machine that removes heat from a liquid via a vapor-compression, Adsorption refrigeration, or absorption refrigeration cycles. This liquid can then be circulated through a heat exchanger to cool equipment, or another process stream (such as air or process water.

Condenser Water Temperature Control

chilled water could operate with an entering co ndenser water temperature below 50°F, as long as the leaving condenser water temperature is gr eater than or equal to 55°F. If you have chillers with older .

Water Chiller Sizing - What You Need to Know | Parker Hannifin

Oct 25, 2017 · The desired water supply temperature also affects the cooling capacity of the chiller. As the water temperature increases, the cooling capacity will also increase. That means if a unit is rated 10 tons at 45/55/95 conditions, and the desired water temperature .

Chillers | SMC Corporation of America

The HEB is a thermoelectric circulating bath comprised of a controller and liquid tank. Cooling is performed by a refrigerant-free peltier element, with extracted heat removed via facility water connection. Temperature .

Water Chillers - Industrial Chiller & Process Cooling .

Thermal Care is a leading manufacturer of water chillers, process cooling equipment and systems for applications worldwide. As an ISO 9001 certified manufacturer, Thermal Care provides heat transfer .

Chiller | Industrial Chillers | HVAC Chillers | Trane

Trane chillers are relied upon for both comfort and process applications in every corner of the world. Trane products within the EcoWise portfolio are designed to help lower environmental impact with next-generation, low .

The Ultimate Guide to Chiller Systems. Everything You Need .

Chillers provide a continuous flow of coolant to the cold side of a process water system at a desired temperature of about 50°F (10°C). The coolant is then pumped through the process, extracting heat out of one area of a facility (e.g., machinery, process equipment, etc.) as it flows back to the return side of the process water system.

Low Temperature Chillers | BV Thermal Systems

The BV Thermal Systems Low Temperature Chillers offer continuous cooling with a temperature from -40° to +30°C. They are ideal for laboratories, and semiconductor, medical, pilot plants and custom applications that require accurate and precise ultra-low temperature control. Featuring a low profile design with high quality locking casters, the Low Temperature Chillers .

HVAC Water Systems - High Tech

temperature chilled water system was analyzed. The cleanroom facility required 3,900 tons of cooling: 2,370 tons of makeup air cooling, and 1,530 tons of sensible and process cooling. By providing 42°F temperature water for low temperature use and 55°F for medium temperature .

Solid State Cooling Systems: ThermoCube Liquid-to-Liquid

(down to -10°C with low temp option) (up to 65°C with high temp option) Ambient Temperature: 10°C to 40°C non-condensing: Stability / Repeatability: ± 0.05°C at constant load (even near ambient) Cooling Capacity (@ 20°C (with 20°C facility chilled water) Model 400LS: ~350 Watts Model 600LS: ~600 Watts Model 400L: ~400 Watts (discontinued)

Low Temperature Chiller,Glycol Chiller System Manufacturer .

From the name of the low-temperature chiller, we can understand this kind of chiller is for low-temperature cooling purposes. Be different from other regular process chillers, low-temperature chiller offers continuous cooling sources with a steady coolant temperature .

Chilled Water Pumps, Systems and Tank Sets For Process Cooling

Apr 05, 2018 · Chilled Water Pumps, Systems and Tank Sets For The Process Cooling And Plastics Industry. . Depending on the size of the system there may be two or three pumps to supply water or water/glycol to the chillers or cooling towers and to the process. A stand-by pump is recommended in case of pump failure. . Low Temperature Chillers.

LOW TEMPERATURE CHILLERS - Low Temp — Drake Chillers

From outer space to deep ground freezing, Drake has done it all. We have a vast experience with low-temp chillers for every process need. Whether you need calcium chloride chilled to -29°F or fuel chilled to -22°F we are here to help you complete that task. Many chiller companies do not want to work with the complexity of low-temp chillers.

Portable Chillers | Process Chillers | Low Temp Fluid Chillers

11 rows · Low Temperature Fluid Chillers Thermonics portable chillers are a family of highly .