Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Accepted Manuscript

support the microreactor was made of (hydrophilic) silica . microreactor technology.12 Experimental Materials and methods 2,2-Dimethyl-1,3-propanediol (NPG), cethyltrimethylammonium . 3-aminopropyltrimethoxysilane were from Sigma Aldrich. The others chemicals used in support synthesis, immobilisation and .

Electromagnetic stirring in a microbioreactor with non .

Jun 22, 2015 · The cassette provided the interface with the external components for mixing, optical analysis, and fluid supply (Fig. 1(a)). For this, the cassette bottom plate had holes to accommodate the electromagnet cores (Fig.

Thiol-ene Monolithic Pepsin Microreactor with a 3D-Printed .

To improve the sample handling, and reduce cost and preparation time, of peptide mapping LC-MS workflows in protein analytical research, we here investigate the possibility of replacing conventional .

Mechanosensitivity is an essential component of .

Jul 15, 2020 · One frame illustrating a piece of retina with rods is shown in Fig 4A. We measure the retraction of the rods indicated in figure with numbers from 1 to 6. For each rod, we define a segment of the same length (L = 10 μm) along the rod axis (white lines), and we calculate .

Optofluidic planar reactors for photocatalytic water .

Dec 30, 2010 · Device design. In order to enlarge the light absorption area and keep the inherent merit of large surface/volume ratio of microreactors, a planar microfluidic reactor is designed as illustrated in Fig. Fig.1. 1.For simplicity, the planar microfluidic reactor is called microreactor hereafter. The microreactor .

A simple antegrade perfusion method for isolating viable .

The aorta was then clamped with a small straight vascular clamp (Fig. 1B), and the clamped heart was transferred on a perfusion plate (we preferred to use the lid of a plastic multi‐well culture plate) placed on a prewarmed heater‐mat (Natsume Seisakusho, Japan) (Fig.

Isolation of Human Atrial Myocytes for Simultaneous .

Jul 03, 2013 · Studying electrophysiological properties of cardiac ion channels with the patch-clamp technique and the exploration of cellular Ca 2+ handling abnormalities require isolated .

Sodium channels enable fast electrical signaling and .

Aug 15, 2019 · In some experiments, the internal solution also contained 2 mM QX-314-Cl (from Sigma-Aldrich). During all recordings, the tissue was perfused at 2.5 ml min −1 with Ames' solution (Sigma-Aldrich.

TRPV1 channels and the progesterone receptor Sig-1R .

Fig. 1. TRPV1-mediated pain is dependent upon Sig-1R activity. (A) Response to 2.8-µg capsaicin injection into to the hind paw of male mice that had been pretreated for 24 h by intrascapularly .

The Sigma-Aldrich Microreactor Explorer Kit — Made by .

The Sigma-Aldrich glass microreactor with a total inner volume of 0.85 mL features two independent reagent stream inlets (indicated by the green and light yellow peek nuts on Figure 13, the red nut marks the output stream) with a small pre-heating unit of 0.08 mL each, a micromixer unit of 0.03 mL, and a fixed residence time unit (RTU) of 0.66 mL.

Sodium channels enable fast electrical signaling and .

Aug 15, 2019 · In some experiments, the internal solution also contained 2 mM QX-314-Cl (from Sigma-Aldrich). During all recordings, the tissue was perfused at 2.5 ml min −1 with Ames' solution (Sigma-Aldrich.

Optofluidic planar reactors for photocatalytic water .

Optofluidic planar reactors for photocatalytic water treatment using solar energy Lei Lei,1 Ning Wang,1 X. M. Zhang,1,a Qidong Tai,1 Din Ping Tsai,2 and Helen L. W. Chan1 1Department of Applied .

Optofluidic planar reactors for photocatalytic water .

Dec 30, 2010 · Device design. In order to enlarge the light absorption area and keep the inherent merit of large surface/volume ratio of microreactors, a planar microfluidic reactor is designed as illustrated in Fig. Fig.1. 1.For simplicity, the planar microfluidic reactor is called microreactor hereafter. The microreactor .

The Specification and Maturation of Nociceptive Neurons .

Nov 19, 2015 · In the experimental groups for generating sensory neurons (Supplementary Fig. S3), retinoic acid (0.1 μM, Sigma-Aldrich) and BMP4 (1, 5 or 25 ng/ml) were added as described in the .

Reaction and Raman spectroscopic studies of alcohol .

block using a clamp on which flanged Teflon tubes were fitted for inlet and outlet. A ceramic packing containing thermocouples and heat cartridges was used for heating and housing the microreactor assembly. 2.3. Experimental procedures 2.3.1. Reaction in microreactors Liquid alcohol (benzyl alcohol, 99.98%, Sigma–Aldrich.

Electromagnetic stirring in a microbioreactor with non .

Jun 22, 2015 · The cassette provided the interface with the external components for mixing, optical analysis, and fluid supply (Fig. 1(a)). For this, the cassette bottom plate had holes to accommodate the electromagnet cores (Fig.

Open Archive Toulouse Archive Ouverte

2010; Ma et al. 2017). Two main types of microreactor have been employed: continuous flow-based and droplet-based microreactors. In the work of Wagner et al. (2008), a continuous flow-based microreactor .

Simple 3D printed stainless steel microreactors for online .

A simple flow chemistry microreactor with an electrospray ionization tip for real time mass spectrometric reaction monitoring is introduced. The microreactor was fabricated by a laser-based additive manufacturing technique from acid-resistant stainless steel 316L. The functionality of the microreactor .

Open Archive Toulouse Archive Ouverte

2010; Ma et al. 2017). Two main types of microreactor have been employed: continuous flow-based and droplet-based microreactors. In the work of Wagner et al. (2008), a continuous flow-based microreactor .

PTFE-based microreactor system for the continuous .

Figure 1 and Figure S1 in Supporting Information File 1 show the color luminescence under irradiation of ultraviolet light and the photoluminescence of the CsPbX 3 QD solutions made via the PTFE-based microreactor .

Validation and Safety of Visual Restoration by Ectopic .

Jun 12, 2019 · Patch-clamp recordings. Three months after surgery, the macaques were dark adapted for 2–3 h before the experiments. Then, they were saced by overdosing with sodium pentobarbital at 150 mg/kg intracardially. The eyes were enucleated and placed in carboxygenated (5% CO 2 and 95% O 2) Ames' medium (Sigma–Aldrich.

US4767087A - Pipe clamp for the rocking or rigid .

A pipe clamp for rocking or rigid suspension of pipes, which comprises two half-clamps having clamp lugs used for joining the half-clamps and having a connector for receiving a threaded rod. The connector is constructed in bridge-like manner and is fixed to the rounded portion of one half-clamp.

Chemical Engineering Journal

Teflon microreactor with integrated piezoelectric actuator devel-oped at MIT (Massachusetts Institute of Technology) (Fig. 2) [17]. The microreactor is made of Teflon (PTFE) plates, with an inte-grated .

Microreactor Array Device - Europe PMC Article - Europe PMC

Insert a microreactor array slide into the fill & seal device of Figure 1 (Biodesign Institute, ASU, Tempe AZ). Put the O-ring around the slide. Place sealing membrane on top of the O-ring and slide. Place window on top of the sealing membrane and clamp .

Supporting Information Development of a microfluidic .

easily controlled. Three metal clamps made of chrome steel are holding the plates tightly together. The microreactor, disassembled and assembled, is shown in Figure S1. The housing of microreactor was designed and fabricated by dbs. Figure S1: Housing for the PDMS microstructured plate.

(PDF) Photocatalytic Microreactor Using Monochromatic .

Fig. 1 The microfluidic planar reactor mounted on a blue-light panel LED. . (Sigma-Aldrich) was driven by a syringe pump . Applications of microreactor technology for the fine chemical industry.

Marking cells with infrared fluorescent proteins to .

All procedures for dissection and patch clamp recordings were performed in a dark room using an infrared viewer (Nitemere, BE Meyers, WA). For some retinal preparations, biliverdin hydrochloride (25 µM, Number 30891; Sigma-Aldrich.

Ultraviolet-assisted microfluidic generation of .

Mar 15, 2016 · I. INTRODUCTION. Microfluidics has grasped much attention recently in biological analysis, 1 chemical synthesis, 2 drug delivery, 3 thermal sensor, 4 and hydrodynamic mechanisms 5 due to its advantages of low fabrication cost, minimal materials' consumption, and fast continuous processing. 6,7 Among various microfluidic technology that have been developed, microreactor .

Rice Husk Supported Catalysts for Degradation of .

Chlorinated organic pollutants are persistent, toxic, and ubiquitously distributed environmental contaminants. These compounds are highly bioaccumulative and adversely affect the ozone layer in the atmosphere. As such, their widespread usage is a major cause of environmental and health concern. Therefore, it is important to detoxify such compounds by environment friendly methods. In this work .

Reaction and Raman spectroscopic studies of alcohol .

block using a clamp on which flanged Teflon tubes were fitted for inlet and outlet. A ceramic packing containing thermocouples and heat cartridges was used for heating and housing the microreactor assembly. 2.3. Experimental procedures 2.3.1. Reaction in microreactors Liquid alcohol (benzyl alcohol, 99.98%, Sigma–Aldrich) was