Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Bioreactor Parts- Chemglass Life Sciences

Bioreactor Replacement Parts for Applikon Biotechnology® and Broadley-James® Brand Reactors. Chemglass Life Sciences is pleased to announce the availability of like-for-like, replacement components for the popular 2, 3, 5, 7 and 15 liter sizes of Applikon and Broadley-James stirred tank bioreactors.

Catalogo laboratorio general by DIEGO PARRA -

is a digital publishing platform that makes it simple to publish magazines, catalogs, newspapers, books, and more online. Easily share your publications and get them in front of 's .

Autoclavable bioreactors-Applitech Pharmaceutical .

Glass autoclavable bioreactors Introduction In the laboratory bioreactor and fermentor range Applikon is worldwide market leader because of its dependable and easy to use systems. The bioreactors and fermentors excel in quality and modularity. An Applikon laboratory system is easy to upgrade if a change in research activities occurs.

Autoclavable bioreactors-Applitech Pharmaceutical .

Glass autoclavable bioreactors Introduction In the laboratory bioreactor and fermentor range Applikon is worldwide market leader because of its dependable and easy to use systems. The bioreactors and fermentors excel in quality and modularity. An Applikon laboratory system is easy to upgrade if a change in research activities occurs.

Autoclave glass 1-20 l

Abacus offers glass autoclavable bioreactors for cell culture applications and glass autoclavable fermentors for microbial culture applications. The systems are built according to the specific demands of a process using an extensive array of standard components. . Glass bioreactor vessels can be used up to 0.5 barg (7.25 psig) of overpressure .

APPK_overview broch_2010.indd - IUL Instruments

Number of Cultures. From micro-scale to full scale production. in the shortest possible time. Traditional early stage process development in bioreactors requires that 'the many' be reduced to

labinstruments.su

3 We Know Bioprocessing BioBLU® Single-Use Vessels – Dependability through proven design With renowned polymer expertise, Eppendorf is proud to offer the largest portfolio of r

Products_and_Solutions_for_the_Biopharmaceutical_Industry .

Due to the use of standard | Vessel holder Motor Adaptor existing sensors automatic control is executed The UniVessel® SU can be used with most by the controller just like with a standard bioreactor controllers for autoclavable bio­ glass vessel. reactors.

Laboratory Product&Services 2012_29.03.indd

Manuals and free instruction guides. Find the user manual.

Uniwersytet Gdański - University of Gdańsk | Uniwersytet .

1050 1050 1 1050 0.08 1134. 4920000024 1050 1050 1 1050 0.08 1134. 4920000032 1050 1050 1 1050 0.08 1134. 4920000040 1050 1050 1 1050 0.08 1134. 4920000059 1050 1050 .

Process Analytics Catalog - PDF Free Download

8 Ingold Leading Process Analytics Ingold has a long track record of innovative high-quality solutions for demanding process analytics applications. Ingold was founded in 1948 by Dr. Werner Ingold. Today, Ingold provides the broadest range of in-line analytical measurement solutions for industrial processes in the biotechnology, pharmaceutical, chemical, and beverage industries.

Products and Solutions for the Biopharmaceutical Industry

Download Products and Solutions for the Biopharmaceutical Industry . 1. 2

Autoclavable Stainless Steel - Asistec

When the application changes, the bioreactor set-up can easily be adapted to the changed process demands. Headplates are made of 316L stainless steel and all parts in the bioreactors have an electropolished finish that ensures reliable cleanability of the vessel and components. Vessels can be used up to 3.1 barg of overpressure. Ports:

i l Process Analytics Catalog

Operating pressure 15 barg @ 25 °C, 7 barg @ 130 °C (0 to 217 psig @ 77 °F, 101 psig @ 266 °F) Cable connection ISM: K8S; Analog: VP Process connection Pg 13.5 thread Reference system Argenthal Type of junction Open junction with direct contact to media Reference electrolyte Xerolyt ® Extra. Lengths 120 mm, 225 mm, 425 mm

For staff

"Type","Name","Description","Related Facility ID","Technique","Location","Contact Name","Contact Telephone","Contact URL","Contact Email","Secondary Contact Name .

For staff

"Type","Name","Description","Related Facility ID","Technique","Location","Contact Name","Contact Telephone","Contact URL","Contact Email","Secondary Contact Name .

Sartorius - Free Download PDF Ebook

Download Sartorius. Report this link. Comments

Glass Autoclavable Bioreactor - Spinco Biotech

Applikon offers glass autoclavable bioreactors for cell culture applications and glass autoclavablefermentors for microbial culture applications. The systems are built according to the specific demands of a process using an extensive array of standard components. . Glass bioreactor vessels can be used up to 0.5 barg (7.25 psig) of overpressure.

Manual Biostat Cplus Sbt6022-e | Risk | Safety | Avaliação .

manual de biodigestor

Microbial Processes and Products - PDF Free Download

Bio-Rad Protein Assay Kit (Bio-Rad Laboratories, Hercules, CA) or Folin reagent procedure after alkaline lysis of the culture, using bovine serum albumin as a standard (20,21). Preweighed glass fiber filters GF/C (Whatman, Maidstone, UK) and filter holder. Perlite filter aid. Fig. 1. Erythromycin biosynthesis.

Applikon 40l hardware - 123doc

Heater Filter Block valve Ex haust Condensate to Biowas te Steam Supply Condensate to Drain 26 HARDWARE MANUAL AUXILIARIES i-Control for In Situ sterilizable Bioreactors June 2009 6.3 SAMPLE VAVLVE AND DRAIN Samples can be taken from the bioreactor in two different ways: using the Applikon Sampling System using the Applikon Bottom Drain During .

Bioprocessing 2018 19 DS low RBG 11

(1) Catalog 2018/2019 Bioprocess products (2) 3 »Heal, Fuel, and Feed the World.« Stephen Sherwin Bioprocess engineers develop and produce a multitude of products and ingredients available today. Their applications are diverse, and the products can be found in pharmaceutical, chemical, and .

Glass autoclavable bioreactors - Applikon Biotechnology

Glass dished bottom vessels are made of borosilicate glass to guarantee: - resistance to thermal shock - excellent corrosion resistance - smooth, non-porous surface for easy cleaning - optimal transparency for visual inspection of the culture; Glass bioreactor vessels can be used up to 0.5 bar (7.5 psi) of overpressure.

Glass Autoclavable Lab Scale Bioreactors/Fermenter .

Models:BLBIO 5GJAV 7GJAV 10GJAV 15GJAV. working Volume 2-4 Liter 3-5 Liter 5-8 Liter 7-10 Liter

Calaméo - Bioprocess

46 Multi-Use Bioreactors External Connections Balance connection RS232 2 + Feed pumps 0–10 V 4 + External inputs 0–10 V Culture Vessel 2 L 5 L 10 L 15 L 20 L 30 L H:D ratio 2:1 2:1 2:1| 2:1| 2:1| 2:1| 3:1 3:1 3:1 3:1 Total volume 3 6. 8 15 22 30 42 [L] Working volume 0. 9–2 1. 6–5 4. 5–10| 5. 5–15| 7. 5–20| 9. 0–30| 3. 5–10 5 .

Applikon autoclaveerbare bioreactor 2 tot 7 liter manual .

The resulting mixing time in ADI's autoclavable bioreactors for mammalian cell and bacterial culture under average operating conditions (ungassed) is given in the following table. 2-2 IQappiikorf ^ ^ ^ ^ DEPENDABLE INSTRUMENTS USER M A N U A L MIXING AND AERATION Autoclavable Bioreactor 2 - 7 liter October 1994 Applikon Dependable Instruments .

Laboratory Product&Services 2012_29.03.indd

Manuals and free instruction guides. Find the user manual.

ez-Control for Autoclavable Bioreactors 1- 20 L

ez-Control for Autoclavable Bioreactors 1- 20 L

Applikon autoclaveerbare bioreactor 2 tot 7 liter manual .

When over-pressure is applied in the (glass) Applikon 1-7 liter bio-reactors, it is advised to install this relief valve. The pressure at which the relief valve will open can be adjusted manually. Z811302050. 1-7 liter reactor, Ml8 x 1.5 port. Air-outlet pipe: The air-outlet .

ez Control for Autoclavable Bioreactors 1 – 20 L

ez-Control for Autoclavable Bioreactor Systems 1 – 20 L GENERAL September 2008 1 1 GENERAL 1.1 INTRODUCTION The Applikon autoclavable Bioreactor Systems basically consist of the following parts: • an autoclavable Bioreactor with the appropriate auxiliaries like a stirrer assembly, sensors, baffles, an aeration assembly, etc.